| Technical parameters: | Apollo 8000-T1
| Apollo 10K-T1
| Apollo 12K-T1
| Apollo 15K-T1
| Apollo 17K-T1
| Apollo 20K-T1
| Apollo 25K-T1
| Apollo 30K-T1
|
| Input parameters (DC) | ||||||||
| Maximum panel input power recommended (kW) | 12 | 15 | 18 | 22.5 | 25.5 | 30 | 32.5 | 39 |
| Maximum DC input voltage (V) | 1100 | |||||||
| Maximum input current of each MPPT (A) | 16 | 20 | 26 | 32 | ||||
| Short circuit current of each MPPT (A) | 25 | 25 | 39 | 50 | ||||
| Max.Power of each MPPT (kW) | 9.6 | 12 | 15.6 | 19.5 | ||||
| No. of MPPT / strings | 2/1 | 2/2 | 2/2 | 2/2+3 | ||||
| Start-up voltage (V) | 180 | |||||||
| MPPT Voltage range (V) | 160V~1000 | |||||||
| Full-load MPPT Voltage range (V) | 550~850 | |||||||
| Rated input voltage (V) | 600 | |||||||
| Output parameters (AC) | ||||||||
| Rated output power (kW) | 8.8kW@40℃ 8kW@45℃ | 11kW@40℃ 10kW@45℃ | 13.2kW@40℃ 12kW@45℃ | 16.5kW@40℃ 15kW@45℃ | 18.7kW@40℃ 17kW@45℃ | 22kW@40℃ 20kW@45℃ | 27.5kW@40℃ 25kW@45℃ | 33kW@40℃ 30kW@45℃ |
| Maximum apparent power (kVA) | 8.8 | 11 | 13.2 | 16.5 | 18.7 | 22 | 27.5 | 33 |
| Max.output power (kW) | 8.8 | 11 | 13.2 | 16.5 | 18.7 | 22 | 27.5 | 33 |
| Output connection type | 3W+PE or 3W+N+PE | |||||||
| Rated voltage/Voltage range (V) | 380/320~480 | |||||||
| Rated grid frequency | 45~55Hz / 55~ 65Hz (According to local grid standards) | |||||||
| Rated output current (A) | 12.2 | 15.2 | 18.2 | 22.8 | 25.8 | 30.4 | 38.0 | 45.6 |
| Maximum output current (A) | 13.4 | 16.7 | 20.1 | 25.1 | 28.4 | 33.4 | 41.8 | 50.1 |
| Power Factor (settable) | > 0.99 @ full power (adjustable range: 0.8 leading ~ 0.8 lagging) | |||||||
| Total Harmonic Distortion THDi (full load) | <3% (full load) | |||||||
| MPPT efficiency | Efficiency 99.9% | |||||||
| Maximum efficiency | 98.4% | 98.5% | 98.6% | 98.6% | ||||
| Euro. efficiency | 97.8% | 98.0% | 98.1% | 98.2% | ||||
| China efficencty | 97.5% | 97.8% | 98.0% | 98.0% | ||||
| DC switch with Shunt release | Protection function Available | |||||||
| Output short circuit protection | Available | |||||||
| Power grid fault monitoring | Available | |||||||
| DC reverse connection protection | Available | |||||||
| String monitoring | Available | |||||||
| DC lightning protection | type II | |||||||
| AC lightning protection | type II | |||||||
| DC insulation impedance detection | Available | |||||||
| AC leakage current detection | Available | |||||||
| Over-temperature protection | Available | |||||||
| DC component monitoring | Available | |||||||
| DC fuse | / | |||||||
| Islanding detection | Available | |||||||
| Smart IV diagnosis | Available | |||||||
| Arc fault detection | Optional | |||||||
| Bus voltage monitoring | Available | |||||||
| PID repair and protection | Optional | |||||||
| Low Voltage Ride Through | Available | |||||||
| Arc fault detection | Option | |||||||
| Remote upgrade and setup | Available | |||||||
| anti-counterflow meter | Available | |||||||
| Fault recorded | Available | |||||||
| Nighttime SVG features | Optional | |||||||
| Display mode | Display and communication LED+bluetooth+APP | |||||||
| Communication mode | RS485/4G/WIFI | |||||||
| General parameters | ||
| Dimension (mm)(W×H×D) | 430×380×180 | |
| Weight (kg) | 17 | 17 |
| Operating temperature range | -30℃~+60℃ (>45°Derating use) | |
| Cooling mode | Air colling without fan | Intelligent air cooling with Fan |
| Maximum altitude for product operation | 4000m (>2000m Rating reduction occurs) | |
| Relative Humidity | 0~100% | |
| Input terminal | MC4 (Amphenol) | |
| Output terminal | OT/DT terminal(Max.50mm2 cable section) | |
| Degree of protection | IP66 | |
| Self power consumption at night | <1W | |
| Noise (dB) | <35 | <40 |
| Topology | no transformer | |
| Certification | |
| Standards | NBT32004,IEC62109,IEC61727,IEC61683,IEC62116 |
| Warranty | 5 Year Product Warranty, 10 Year Performance Warranty |
No questions yet. Be the first to ask!






Leave your information and we'll notify you as soon as this product is back in stock.

There are no reviews yet.
There are no questions yet.
Ask the seller now and their answer will show here.
| Technical parameters: | Apollo 8000-T1
| Apollo 10K-T1
| Apollo 12K-T1
| Apollo 15K-T1
| Apollo 17K-T1
| Apollo 20K-T1
| Apollo 25K-T1
| Apollo 30K-T1
|
| Input parameters (DC) | ||||||||
| Maximum panel input power recommended (kW) | 12 | 15 | 18 | 22.5 | 25.5 | 30 | 32.5 | 39 |
| Maximum DC input voltage (V) | 1100 | |||||||
| Maximum input current of each MPPT (A) | 16 | 20 | 26 | 32 | ||||
| Short circuit current of each MPPT (A) | 25 | 25 | 39 | 50 | ||||
| Max.Power of each MPPT (kW) | 9.6 | 12 | 15.6 | 19.5 | ||||
| No. of MPPT / strings | 2/1 | 2/2 | 2/2 | 2/2+3 | ||||
| Start-up voltage (V) | 180 | |||||||
| MPPT Voltage range (V) | 160V~1000 | |||||||
| Full-load MPPT Voltage range (V) | 550~850 | |||||||
| Rated input voltage (V) | 600 | |||||||
| Output parameters (AC) | ||||||||
| Rated output power (kW) | 8.8kW@40℃ 8kW@45℃ | 11kW@40℃ 10kW@45℃ | 13.2kW@40℃ 12kW@45℃ | 16.5kW@40℃ 15kW@45℃ | 18.7kW@40℃ 17kW@45℃ | 22kW@40℃ 20kW@45℃ | 27.5kW@40℃ 25kW@45℃ | 33kW@40℃ 30kW@45℃ |
| Maximum apparent power (kVA) | 8.8 | 11 | 13.2 | 16.5 | 18.7 | 22 | 27.5 | 33 |
| Max.output power (kW) | 8.8 | 11 | 13.2 | 16.5 | 18.7 | 22 | 27.5 | 33 |
| Output connection type | 3W+PE or 3W+N+PE | |||||||
| Rated voltage/Voltage range (V) | 380/320~480 | |||||||
| Rated grid frequency | 45~55Hz / 55~ 65Hz (According to local grid standards) | |||||||
| Rated output current (A) | 12.2 | 15.2 | 18.2 | 22.8 | 25.8 | 30.4 | 38.0 | 45.6 |
| Maximum output current (A) | 13.4 | 16.7 | 20.1 | 25.1 | 28.4 | 33.4 | 41.8 | 50.1 |
| Power Factor (settable) | > 0.99 @ full power (adjustable range: 0.8 leading ~ 0.8 lagging) | |||||||
| Total Harmonic Distortion THDi (full load) | <3% (full load) | |||||||
| MPPT efficiency | Efficiency 99.9% | |||||||
| Maximum efficiency | 98.4% | 98.5% | 98.6% | 98.6% | ||||
| Euro. efficiency | 97.8% | 98.0% | 98.1% | 98.2% | ||||
| China efficencty | 97.5% | 97.8% | 98.0% | 98.0% | ||||
| DC switch with Shunt release | Protection function Available | |||||||
| Output short circuit protection | Available | |||||||
| Power grid fault monitoring | Available | |||||||
| DC reverse connection protection | Available | |||||||
| String monitoring | Available | |||||||
| DC lightning protection | type II | |||||||
| AC lightning protection | type II | |||||||
| DC insulation impedance detection | Available | |||||||
| AC leakage current detection | Available | |||||||
| Over-temperature protection | Available | |||||||
| DC component monitoring | Available | |||||||
| DC fuse | / | |||||||
| Islanding detection | Available | |||||||
| Smart IV diagnosis | Available | |||||||
| Arc fault detection | Optional | |||||||
| Bus voltage monitoring | Available | |||||||
| PID repair and protection | Optional | |||||||
| Low Voltage Ride Through | Available | |||||||
| Arc fault detection | Option | |||||||
| Remote upgrade and setup | Available | |||||||
| anti-counterflow meter | Available | |||||||
| Fault recorded | Available | |||||||
| Nighttime SVG features | Optional | |||||||
| Display mode | Display and communication LED+bluetooth+APP | |||||||
| Communication mode | RS485/4G/WIFI | |||||||
| General parameters | ||
| Dimension (mm)(W×H×D) | 430×380×180 | |
| Weight (kg) | 17 | 17 |
| Operating temperature range | -30℃~+60℃ (>45°Derating use) | |
| Cooling mode | Air colling without fan | Intelligent air cooling with Fan |
| Maximum altitude for product operation | 4000m (>2000m Rating reduction occurs) | |
| Relative Humidity | 0~100% | |
| Input terminal | MC4 (Amphenol) | |
| Output terminal | OT/DT terminal(Max.50mm2 cable section) | |
| Degree of protection | IP66 | |
| Self power consumption at night | <1W | |
| Noise (dB) | <35 | <40 |
| Topology | no transformer | |
| Certification | |
| Standards | NBT32004,IEC62109,IEC61727,IEC61683,IEC62116 |
| Warranty | 5 Year Product Warranty, 10 Year Performance Warranty |







Reviews
There are no reviews yet.