

| Technical parameters: | Venus 4000-S1 | Venus 5000-S1 | Venus 6000-S1 |
| Battery specifications | |||
| Battery type | lithium ion battery, lead-acid battery | ||
| Battery rated voltage | 48 V | ||
| Battery voltage range | 42-58 V | ||
| Battery capacity recommended | 50-2000 Ah | ||
| Maximum charging and discharging power | 4000 W | 5000 W | 5000 W |
| Maximum charging current | 100 A (settable) | ||
| Maximum discharging current | 100A (adjustable) | ||
| Charging curve (lithium ion battery) | BMS | ||
| Charging curve (lead-acid battery) | 3-stage adaptive maintenance | ||
| Depth of Discharge | lithium ion battery: 0-90% adjustable, lead-acid battery: 0-50% adjustable | ||
| Maximum DC power of single channel MPPT | 3500 W | ||
| Maximum input voltage | 600 V | ||
| Start-up input voltage | 100 V | ||
| Rated input voltage | 360 V | ||
| MPPT voltage range | 120 V- 580 V | ||
| Full load DC voltage range | 200 V-520 V | 250 V-520 V | 300 V-520 V |
| Number of independent MPPT | 2 | ||
| Number of DC inputs | 1/1 | ||
| Maximum input current | 13 A/13 A | ||
| Maximum short circuit current | 18 A /18 A | ||
| Maximum AC power | 4400 VA | 5500 VA | 6000 VA |
| Maximum output current | 20 A | 25 A | 27.3 A |
| Nominal grid voltage | L/N/PE, 220 VAC, 230 VAC, 240 VAC | ||
| Nominal AC voltage range | 180 VAC-276 VAC (according to local standard) | ||
| Rated grid frequency | 50 Hz/ 60 Hz | ||
| Grid frequency range | 45 Hz-55 Hz/54 Hz-66 Hz (according to local standard ) | ||
| Active power adjustable range | 0~ 100% | ||
| Total harmonic component (current) | <3% | ||
| Power Factor | 1 (+/-0.8 adjustable) | ||
| Maximum output current | 18.2 | 22.7 | 22.7 |
| Peak output power, time | 4800 VA,60 s | 6000 VA,60 s | 6000 VA,60 s |
| Nominal output voltage, frequency | 220 V/230 V,50/60 Hz | ||
| Voltage total harmonic distortion (@ linear load) | <3% | ||
| Switching time | <10 ms | ||
| European weighted efficiency | <97.20% | <97.30% | <97.50% |
| Maximum charging and discharging efficiency of battery | <94.00% | ||
| MPPT efficiency | >99.9% | ||
| DC reverse connection protection | available | ||
| Ground fault monitoring | available | ||
| Over-current protection | available | ||
| DC switch | available | ||
| Battery soft start protection | available | ||
| AFCI protection | optional | ||
| Lightning protection | Class III | ||
| Ambient temperature range | General parameters -30 ~ + 60 ℃ (Rating reduction occurs when the ambient temperate rises above 45 ℃.) |
| Stand-by loss | <10 W |
| Topology | high frequency isolation |
| Degrees of protection | IP65 |
| Relative Humidity range allowed | 0~ 100% |
| Communication | CAN 2.0/RS 485, Wi-Fi/GPRS (optional) |
| Protection level | Class I |
| Maximum altitude for product operation | <4000 m |
| Connection mode of current sensor | external |
| Noise | <29 dB |
| Weight | 27 kg |
| Cooling mode | natural cooling |
| Dimension (mm) | 540*380*185 |
| Display | LCD & APP |
| Warranty | 5 years (extendable) |
| Standard | |
| EMC | EN 61000-6-1, EN 61000-6-3 |
| Safety regulations and standards | IEC62109-1,IEC62109-2 |
| Grid-connection standard | IEC61727,IEC62116,IEC-61683,VDE-AR-N 4105, VDE V 0124-100,AS4777 |
No questions yet. Be the first to ask!






Leave your information and we'll notify you as soon as this product is back in stock.

There are no reviews yet.
There are no questions yet.
Ask the seller now and their answer will show here.
| Technical parameters: | Venus 4000-S1 | Venus 5000-S1 | Venus 6000-S1 |
| Battery specifications | |||
| Battery type | lithium ion battery, lead-acid battery | ||
| Battery rated voltage | 48 V | ||
| Battery voltage range | 42-58 V | ||
| Battery capacity recommended | 50-2000 Ah | ||
| Maximum charging and discharging power | 4000 W | 5000 W | 5000 W |
| Maximum charging current | 100 A (settable) | ||
| Maximum discharging current | 100A (adjustable) | ||
| Charging curve (lithium ion battery) | BMS | ||
| Charging curve (lead-acid battery) | 3-stage adaptive maintenance | ||
| Depth of Discharge | lithium ion battery: 0-90% adjustable, lead-acid battery: 0-50% adjustable | ||
| Maximum DC power of single channel MPPT | 3500 W | ||
| Maximum input voltage | 600 V | ||
| Start-up input voltage | 100 V | ||
| Rated input voltage | 360 V | ||
| MPPT voltage range | 120 V- 580 V | ||
| Full load DC voltage range | 200 V-520 V | 250 V-520 V | 300 V-520 V |
| Number of independent MPPT | 2 | ||
| Number of DC inputs | 1/1 | ||
| Maximum input current | 13 A/13 A | ||
| Maximum short circuit current | 18 A /18 A | ||
| Maximum AC power | 4400 VA | 5500 VA | 6000 VA |
| Maximum output current | 20 A | 25 A | 27.3 A |
| Nominal grid voltage | L/N/PE, 220 VAC, 230 VAC, 240 VAC | ||
| Nominal AC voltage range | 180 VAC-276 VAC (according to local standard) | ||
| Rated grid frequency | 50 Hz/ 60 Hz | ||
| Grid frequency range | 45 Hz-55 Hz/54 Hz-66 Hz (according to local standard ) | ||
| Active power adjustable range | 0~ 100% | ||
| Total harmonic component (current) | <3% | ||
| Power Factor | 1 (+/-0.8 adjustable) | ||
| Maximum output current | 18.2 | 22.7 | 22.7 |
| Peak output power, time | 4800 VA,60 s | 6000 VA,60 s | 6000 VA,60 s |
| Nominal output voltage, frequency | 220 V/230 V,50/60 Hz | ||
| Voltage total harmonic distortion (@ linear load) | <3% | ||
| Switching time | <10 ms | ||
| European weighted efficiency | <97.20% | <97.30% | <97.50% |
| Maximum charging and discharging efficiency of battery | <94.00% | ||
| MPPT efficiency | >99.9% | ||
| DC reverse connection protection | available | ||
| Ground fault monitoring | available | ||
| Over-current protection | available | ||
| DC switch | available | ||
| Battery soft start protection | available | ||
| AFCI protection | optional | ||
| Lightning protection | Class III | ||
| Ambient temperature range | General parameters -30 ~ + 60 ℃ (Rating reduction occurs when the ambient temperate rises above 45 ℃.) |
| Stand-by loss | <10 W |
| Topology | high frequency isolation |
| Degrees of protection | IP65 |
| Relative Humidity range allowed | 0~ 100% |
| Communication | CAN 2.0/RS 485, Wi-Fi/GPRS (optional) |
| Protection level | Class I |
| Maximum altitude for product operation | <4000 m |
| Connection mode of current sensor | external |
| Noise | <29 dB |
| Weight | 27 kg |
| Cooling mode | natural cooling |
| Dimension (mm) | 540*380*185 |
| Display | LCD & APP |
| Warranty | 5 years (extendable) |
| Standard | |
| EMC | EN 61000-6-1, EN 61000-6-3 |
| Safety regulations and standards | IEC62109-1,IEC62109-2 |
| Grid-connection standard | IEC61727,IEC62116,IEC-61683,VDE-AR-N 4105, VDE V 0124-100,AS4777 |







Reviews
There are no reviews yet.