| Technical parameters: | Mercury 3680-S1 | Mercury 5000-S1 | Mercury 6000-S1 |
| Input (DC) | |||
| Maximum panel input power recommended | 4900 Wp | 7500 Wp | 9000 Wp |
| Maximum DC power of single channel MPPT | 2400 W | 3000 W | 3150 W |
| Maximum input voltage | 600 V | ||
| Start-up input voltage | 120 V | ||
| Rated input voltage | 360 V | ||
| MPPT voltage range | 90 V-550 V | ||
| Full load DC voltage range | 165 V-500 V | 175 V-500 V | 250 V-520 V |
| Number of independent MPPT | 2 | ||
| Number of DC inputs | 1/1 | ||
| Maximum Input current | 13 A/13 A | ||
| Maximum short circuit current | 18 A /18 A | ||
| Rated output power | 3680 W | 5000 W | 6000 W |
| Maximum output current | 16 A | 25 A | 27.3 A |
| Nominal grid voltage | L/N/PE, 220Vac, 230Vac, 240Vac | ||
| Nominal AC voltage range | 180 VAC-276 VAC (according to local standard) | ||
| Rated grid frequency | 50 Hz/ 60 Hz | ||
| Grid frequency range | 45 Hz-55 Hz/54 Hz-66 Hz (according to local standard) | ||
| Active power adjustable range | 0~100% | ||
| Total harmonic component (current) | <3% | ||
| Power Factor | 1 (+/-0.8 adjustable) | ||
| Efficiency | |||
| Maximum efficiency | 97.60% | 97.80% | 98.00% |
| European weighted efficiency | 97.20% | 97.30% | 97.30% |
| MPPT efficiency | >99.9% | ||
| available | |||
| DC reverse connection protection | available | ||
| Ground fault monitoring | available | ||
| Over-current protection | available | ||
| DC switch | available | ||
| Battery soft start protection | available | ||
| AFCI protection | optional | ||
| Ambient temperature range -30 ~ + 60 ℃ (Rating reduction occurs when the ambient temperate rises above 45 ℃.) | |||
| Stand-by loss | <10 W | ||
| Topology | no transformer | ||
| Degrees of protection | IP65 | ||
| Relative Humidity range allowed | 0~100% | ||
| Communication | RS 485, Wi-Fi/GPRS (optional) | ||
| Protection level | Class I | ||
| Maximum altitude for product operation | 2000 m | ||
| Connection mode of current sensor | external | ||
| Noise | <29 dB | ||
| Weight | 11 kg | ||
| Cooling mode | natural cooling | ||
| Dimension (mm) | 380*380*150 | ||
| Display | LCD & APP | ||
| Warranty | 5 years (extendable) | ||
| Standard | |
| EMC | EN 61000-6-1, EN 61000-6-3 |
| Safety regulations and standards | IEC62109-1,IEC62109-2 |
| Grid-connection standard | IEC61727,IEC62116,IEC-61683,VDE-AR-N 4105, VDE V 0124-100,AS4777 |
No questions yet. Be the first to ask!






Leave your information and we'll notify you as soon as this product is back in stock.

There are no reviews yet.
There are no questions yet.
Ask the seller now and their answer will show here.
| Technical parameters: | Mercury 3680-S1 | Mercury 5000-S1 | Mercury 6000-S1 |
| Input (DC) | |||
| Maximum panel input power recommended | 4900 Wp | 7500 Wp | 9000 Wp |
| Maximum DC power of single channel MPPT | 2400 W | 3000 W | 3150 W |
| Maximum input voltage | 600 V | ||
| Start-up input voltage | 120 V | ||
| Rated input voltage | 360 V | ||
| MPPT voltage range | 90 V-550 V | ||
| Full load DC voltage range | 165 V-500 V | 175 V-500 V | 250 V-520 V |
| Number of independent MPPT | 2 | ||
| Number of DC inputs | 1/1 | ||
| Maximum Input current | 13 A/13 A | ||
| Maximum short circuit current | 18 A /18 A | ||
| Rated output power | 3680 W | 5000 W | 6000 W |
| Maximum output current | 16 A | 25 A | 27.3 A |
| Nominal grid voltage | L/N/PE, 220Vac, 230Vac, 240Vac | ||
| Nominal AC voltage range | 180 VAC-276 VAC (according to local standard) | ||
| Rated grid frequency | 50 Hz/ 60 Hz | ||
| Grid frequency range | 45 Hz-55 Hz/54 Hz-66 Hz (according to local standard) | ||
| Active power adjustable range | 0~100% | ||
| Total harmonic component (current) | <3% | ||
| Power Factor | 1 (+/-0.8 adjustable) | ||
| Efficiency | |||
| Maximum efficiency | 97.60% | 97.80% | 98.00% |
| European weighted efficiency | 97.20% | 97.30% | 97.30% |
| MPPT efficiency | >99.9% | ||
| available | |||
| DC reverse connection protection | available | ||
| Ground fault monitoring | available | ||
| Over-current protection | available | ||
| DC switch | available | ||
| Battery soft start protection | available | ||
| AFCI protection | optional | ||
| Ambient temperature range -30 ~ + 60 ℃ (Rating reduction occurs when the ambient temperate rises above 45 ℃.) | |||
| Stand-by loss | <10 W | ||
| Topology | no transformer | ||
| Degrees of protection | IP65 | ||
| Relative Humidity range allowed | 0~100% | ||
| Communication | RS 485, Wi-Fi/GPRS (optional) | ||
| Protection level | Class I | ||
| Maximum altitude for product operation | 2000 m | ||
| Connection mode of current sensor | external | ||
| Noise | <29 dB | ||
| Weight | 11 kg | ||
| Cooling mode | natural cooling | ||
| Dimension (mm) | 380*380*150 | ||
| Display | LCD & APP | ||
| Warranty | 5 years (extendable) | ||
| Standard | |
| EMC | EN 61000-6-1, EN 61000-6-3 |
| Safety regulations and standards | IEC62109-1,IEC62109-2 |
| Grid-connection standard | IEC61727,IEC62116,IEC-61683,VDE-AR-N 4105, VDE V 0124-100,AS4777 |